Eurocode 5 span tables for solid timber members in floors ceilings and roofs for dwellings 3rd edition.
Flat roof joist span tables uk.
Span is clear span between supports.
Joist breadth 47mm.
For timber floors between homes.
Timber to be covered these span tables do not apply to timber which is fully exposed to the elements.
The section sizes are based on regularised als or cls timber.
Other span tables are based on.
The floor joist span tables are based on the loadings given in the amended version of bs 6399 1 which is an imposed load of either a uniformly distributed load of 1 5 kn m or a concentrated load of 1 4 kn.
At least 40mm bearing on supports.
Flat roof joists rafters purlin.
Should refer to trada document span tables for solid timber members in floors ceilings and roofs excluding trussed rafter roofs for dwellings or ask your lbc surveyor for advice.
Span tables for solid timber joists.
For pitched roofs flat roofs and ceiling joists.
This table uses commonly available uk regularised timber depths.
Floor joists flat roof joists assumptions at 400mm centers supporting permanent load excluding self weight of joists up to 50kg m2.
Supporting imposed load for access and repair only.
Maximum slop3 10 deg.
Notches are not to exceed 0 125 of the depth of the joist and are to be located between 0 07 and 0 25 of the span from the support.
Surveyors span tables for designing roof rafters.
Tables 1 and 2 in this chapter are derived from the trada technology ltd.
Span tables for flat roof joists to bs 5268 7 2 imposed loads of 0 75 kn m for maintenance and snow load are applicable where there is no permanent access no fixed ladder or staircase and most areas where the altitude does not exceed 100 metres refer to bs 6399 3.